An intermittent hydraulic machine can look easy to size: it runs for a short part of each cycle, rests, and never seems to demand continuous power. That assumption often leads to an HPU with enough peak pressure and flow to move the actuator, but not enough motor capacity, reservoir volume, or heat rejection to survive repeated cycling. The result may be slow recovery between strokes, unstable pressure, nuisance relief-valve operation, and oil that grows hotter over the shift.
The correct approach is to size the hydraulic power unit around the full duty cycle, not the briefest peak event. Start with the highest required flow and pressure, then calculate average hydraulic power, motor loading, accumulator contribution where applicable, reservoir behavior, and heat generation. What causes hydraulic power unit oil temperature to rise? In intermittent service, the usual causes are prolonged relief flow, throttling losses, an oversized pump running unloaded, insufficient reservoir dwell time, poor cooling, internal leakage, or a motor-pump combination selected only for peak flow without regard to cycle energy.
Intermittent duty means the unit does not run at one steady flow and pressure. A press may approach quickly at low pressure, build force at high pressure and low flow, hold for a period, retract, and wait for the next part. A clamp circuit may have a short, high-flow closing movement followed by a lower-flow pressure hold. Each phase loads the pump, motor, valves, and oil differently.
Before selecting components, break the cycle into operating segments. For each segment, record:
This information reveals a critical distinction: a system can require high peak hydraulic power while consuming moderate average power. Intermittent duty often allows a smaller motor than a continuous-duty calculation would suggest, but only when the motor’s permissible overload, starts per hour, thermal class, and actual off-time support that decision. It does not automatically justify a small reservoir or omit cooling.
For a cylinder, required flow is based on effective piston area and target velocity:
Q = A × v
where Q is flow, A is the effective cylinder area, and v is rod speed. Use the full-bore area for extension and the annulus area for retraction. Convert the result into the unit used by the pump supplier, typically L/min or gal/min. A common sizing error is to use bore area for both directions, which overstates retraction flow for a single-rod cylinder.
For a hydraulic motor, flow is related to displacement and speed. Include expected volumetric losses, especially where operating pressure, oil temperature, and motor wear can reduce delivered speed. The pump must provide enough flow at the actual operating condition, not only at its theoretical displacement.
Then add realistic allowances for leakage and control functions. A proportional valve, pilot circuit, flushing flow, cooling loop, or pressure-compensator standby flow may be small individually but can matter in a low-duty system where the principal actuator moves only briefly.
Cylinder force determines only part of the pressure requirement. The HPU must overcome load pressure plus losses through directional valves, proportional valves, hoses, filters, manifolds, quick couplings, and return plumbing. At higher flow, restrictions can produce substantial pressure drop and heat. A circuit that works during commissioning at moderate speed may overheat when production demands faster travel because valve losses rise sharply with flow.
Estimate required actuator pressure from:
Pressure = Force ÷ Effective Area
Then add pressure losses for the flow path active during that motion. Relief setting should sit above the highest legitimate working pressure with an appropriate margin, but it should not be used as the normal means of controlling speed or force. A relief valve passing significant flow during every cycle converts hydraulic power directly into heat.
Hydraulic power can be estimated as:
Power (kW) = Pressure (bar) × Flow (L/min) ÷ 600
For preliminary calculations, this gives hydraulic output power. Divide by the combined efficiency of pump, coupling, motor, and any relevant drive components to estimate electrical input and motor demand. Efficiency varies with pressure, speed, fluid viscosity, and component type, so use supplier performance curves for final selection rather than assuming one fixed value.

A pump selected for the maximum flow and maximum pressure at the same time may be unnecessarily large if those conditions never coincide. Conversely, sizing a motor only from average power can be unsafe when a short high-load portion of the cycle requires more torque than the motor can deliver without excessive speed drop or overheating.
To find average hydraulic power, calculate the energy used in each segment: hydraulic power multiplied by segment time. Add the segment energies, divide by total cycle time, and then account for losses. Include the periods where the motor runs but the actuator does no useful work. This is often where an apparently intermittent unit becomes a heat problem.
Fixed-displacement pumps are straightforward and can be effective where flow demand is stable or the motor can stop between cycles. Their weakness appears when the pump continues delivering flow against an unloading valve, pressure-compensated restriction, or relief valve for long periods. The fluid may circulate continuously even though production motion is intermittent.
Variable-displacement pressure-compensated pumps can reduce wasted flow during high-pressure hold periods, but they still generate standby losses and require correct compensator settings, cleanliness, and stable system design. Load-sensing arrangements can better match flow to demand in circuits with variable speeds or multiple functions, although their control complexity must fit the application.
An accumulator is useful when a short burst of flow or power exceeds what a practical motor can supply continuously. The motor-pump group charges the accumulator during lower-demand portions of the cycle, and stored fluid supports the peak event. This can reduce installed motor size or improve response, but it adds precharge maintenance, safety isolation, pressure monitoring, and a careful usable-volume calculation. It is not simply a substitute for identifying where energy is being wasted.
For simple short-cycle equipment, stopping the motor after pressure is reached may be the most efficient option, provided pressure decay, restart frequency, motor starting duty, and process response permit it. A pressure switch, pressure transducer, or programmable control sequence must be set to avoid rapid cycling around a narrow pressure band.
The old rule of selecting reservoir capacity as a multiple of pump flow is only a starting point. It may produce an oversized tank in a low-energy circuit or an undersized one in a compact high-pressure installation. Reservoir volume should allow sufficient dwell time for air release, contamination settling where relevant, and cooling, while maintaining a stable suction condition through the lowest operating level.
A small tank can be acceptable when the circuit has effective filtration, controlled return flow, adequate cooling, and a pump arrangement that does not entrain air. Yet a reservoir made small solely to reduce footprint often leaves little thermal buffer. When cycle rate rises, oil temperature can climb quickly because the tank surface cannot reject accumulated losses.
Consider the working fluid level rather than nominal tank volume. Cylinder extension and retraction can shift a meaningful amount of oil between the reservoir and actuator. Account for the largest cylinder differential volume, accumulator exchange, drain flows, thermal expansion, and a safe margin above the suction connection. Baffles should separate return and suction zones without obstructing maintenance or creating excessive return backpressure.
An oil cooler may be necessary, but it should not conceal a poor energy balance. Heat load is the difference between input power and useful output. During intermittent operation, the most revealing question is often not “How hot is the oil?” but “What is consuming power while the machine is not doing useful work?”
Measure rather than infer where possible. Record reservoir temperature, cooler inlet and outlet temperature, pressure before and after filters, pump case-drain flow where applicable, and pressure during each cycle phase. A stable high oil temperature with a large cooler temperature difference points to a heat-rejection limitation. A small cooler temperature difference while oil remains hot may indicate inadequate coolant flow, fouling, bypass operation, or poor air movement. Rising case-drain flow can indicate a component condition issue, but interpret it against the manufacturer’s allowable limits and test method.
Motor selection for intermittent duty is not just a conversion from hydraulic kW to motor kW. A motor may tolerate short overloads, but the allowable duration depends on its design, starting method, enclosure, ambient temperature, altitude, ventilation, and how completely it cools during idle time. Frequent direct-on-line starts can become a limiting factor even when average running power is low.
Check the torque requirement at the pump shaft during the highest-pressure segment. A pump that is difficult to start against pressure may require an unload-start circuit, a soft-start arrangement, a variable-speed drive, or a different control sequence. Also consider whether a motor must run continuously to provide lubrication, cooling, or control pressure; this changes the thermal calculation from an intermittent motor duty problem into a continuous auxiliary-load problem.
Where the process needs a brief high-flow motion followed by a pressure hold, the best arrangement depends on how often the cycle repeats and how much energy is lost while waiting.
No option is inherently cooler in every installation. A well-controlled fixed-pump circuit can outperform a poorly adjusted variable-displacement system, while an accumulator may be justified by a demanding peak event but unnecessary where a properly selected motor can handle the load directly.
After initial sizing, test the unit at the planned cycle rate long enough for temperatures to stabilize. Verify actual extension and retraction times, pressure at the actuator and pump outlet, motor current, reservoir level, filter restriction, and cooler performance. Repeat the test at the expected warm-oil condition, because pump slip, valve response, leakage, and viscosity-related losses change as temperature rises.
A useful acceptance review asks whether any component is intentionally dissipating power during a normal part of the cycle. Some loss is unavoidable, but sustained relief flow, a constantly throttled bypass, or excessive standby circulation deserves redesign before a larger cooler is specified. The HPU is correctly sized for intermittent duty when it meets the peak motion requirement, remains within component and motor limits across the actual cycle, and rejects its recurring losses without driving the oil beyond the fluid and component temperature limits.